安装好vac之后,在编译的时候提示“1506-507 (W) No licenses available. Contact your program supplier to add additional users. Compilation will proceed shortly”,这是因为没有正确配置LUM(License Use Management)引起的 。
cd /usr/opt/ifor/ls/os/aix/bin
./i4config
From a License Management point of view,
you can choose to configure this system as:
1) Network License Client
2) Nodelock License Server (and/or Network License Client)
3) Network (and/or Nodelock) License Server
4) Central Registry (and/or Network and/or [...]
之前有两台570做的HACMP,使用的DS4800,最近新购DS8000,就把DS4800上的数据迁移到了DS8000上,迁移完之后测试都正常,第二天查看日志出现如下错误:
72206E77 0819080009 P H vpath5 REQUESTED OPERATION CANNOT BE PERFORMED 72206E77 0819080009 P H vpath4 REQUESTED OPERATION CANNOT BE PERFORMED 72206E77 0819080009 P H vpath3 REQUESTED OPERATION CANNOT BE PERFORMED 72206E77 0819080009 P H vpath2 REQUESTED OPERATION CANNOT BE PERFORMED 72206E77 0819080009 P H [...]
一台P550重启之后无法正常启动,远程在HMC上看到一直停留在0c31,又重启一次问题一样,于是检查主机,发现主机内置磁带机中有一盘磁带,于是怀疑是从磁带启动了,把磁带取出来,重新启动正常,进入系统之后查看启动顺序,果然启动顺序磁带在前
# bootlist -m normal –o
机器亮黄灯告警一般是有硬件问题(单电源等可能有安全隐患的硬件配置也可能造成黄灯亮起),见到后首先进行下硬件诊断,方法如下: 诊断系统,
判断是否硬件故障:
1、Root用户执行diag; 2、回车后,进第2项,advanced diagnostics routines; 3、选system verification; 4、选all resources,回车; 5、按F7(或esc+7)进行执行检测; 6、看返回结果,是否存在故障。 如存在故障,记录故障及errpt –a,再做处理。 如无故障,或故障解决后黄灯依然不熄灭,清除警告灯。